UCI hydraulic test rig

What changed in the machine readings?

Compare real recordings, explore what a change could mean, and leave a clear note about what needs checking next.

Spot the change. Decide what to check.

Compare each recording with a stable reference. Try two examples to see why the pattern matters as much as the average.

Public test-rig recordings from UCI. Client telemetry and hardware are kept separate.

Cycle 106560 seconds · Archived measurements

Functional sensor map

MMotorPumpValve / load controlTest loadCooling loopReservoir

Illustrates signal groups and hydraulic roles. Channel mounting locations are not established by this view.

TS1 · Temperature

1 Hz recorded · Original one-second samples · Sustained deviation

Follow the blue measurement against the dashed reference. Replay the recording or move the time slider to inspect a moment. The shaded band is an illustrative comparison range.

45.7942.4439.0835.730s15s30s45s59s
Recorded measurementReferenceComparison band
59s

Bin 59–60s: measured 45.54 °C, reference 36.35 °C. Playback changes the view of an archived cycle.

45.51 °CFull-cycle mean
+9.23 °CDifference from reference
60sOutside comparison band
ChannelCycle meanReferenceDifferenceOutside band
158.68 bar161.00-2.3160/60 s
2456 W2533-7860/60 s
6.66 L/min6.71-0.042/60 s
45.51 °C36.28+9.2360/60 s
0.598 mm/s0.553+0.04646/60 s
Data source, reference method and limits

UCI hydraulic systems dataset · Helwig, Pignanelli & Schütze · CC BY 4.0. Display aggregation modifies the original sampling resolution.

Nine separate stable cycles form the phase-aligned mean and sample-standard-deviation reference. Original reference rows: 1788, 1789, 1790, 1791, 1792, 1793, 1794, 1795, 1796. The healthy displayed cycle is held out.

Comparison band: reference mean ± max(3 × sample standard deviation, channel-specific minimum tolerance). For TS1: 0.25 °C. These are illustrative screening parameters, not manufacturer alarm limits.

Recorded component labels describe the experiment. The functional illustration is not a verified mounting diagram. This benchmark is separate from confidential client hardware and telemetry.

Download attributed measurements